Default Factory Settings

To restore default factory settings, print page 34 and scan following barcode

  • RESTORE EU FACTORY CONFIGURATION

 

Enable Pharmaceutical barcode

Print page 148 and scan following barcode:

  • ENTER/EXIT PROGRAMMING MODE
  • CODE32=ENABLE
  • ENTER/EXIT PROGRAMMING MODE

 

Enabling serial  number reading

print page 169 and scan:

  • ENTER/EXIT PROGRAMMING MODE
  • I2OF5=ENABLE
  • ENTER/EXIT PROGRAMMING MODE

To avoid sending check carachter scan:

  • ENTER/EXIT PROGRAMMING MODE
  • I2OF5 Check character Transmission=don't send
  • ENTER/EXIT PROGRAMMING MODE